Quality Standards and Classification
CE. ISO13485
SFDA: Class Ilb
Anti-electroshock degree:Class! equipment (internal power supply)
TEMP/SpO 2 /NIBP: BF
ECG/Resp: CF
Application Range
• Adult/Pediatric/Neonatal (Necllor
Spo2&Suntch Nibp) /Surgery/
Operating Room/ICU/CCU
(Seperated parameter board)
Display
• 12.1″TFT screen
Environment
Operating environment:
Temperature: 0 ~ 40 °C
Humidity: 15% ~ 80%
Pressure: 86.0 kPa ~ 106.0kPa
Transport and Storage environment :
Temperature: -20 ~ 55 °C
Humidity: 10% ~ 90%
Pressure: 86.0 kPa ~ 106.0kPa
Power Requirements
AC: 100 ~ 240V. 50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion battery
2h operating after full charge
5min operating after low battery alarm
Dimension and Weight
Equipment: 305*162*290mm(about);
4kg(about)
Package: 380*350*300mm(about) ;
6kg(about)
Date Storage
Trend diagram/table: 720h
NIBP review: 10000 events
Wave review: 12h
Alam review: 200 alarm events
Support drug concentration titration analysis
ECG
5 Leads: RA, LA, LL, RL, V
Lead mode: 1,II, III, AVR, AVL, AVF, V
Gain: × 1.25mm/mV,2.5mm/mV,
5.0mm/mV, 10mm/mV,
20mm/mV (error 5%)
Sweep speed:
6.25mm/s, 12.5mm/s,25mm/s,
50mm/s (errors #10%)
Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Sensitivity. >200 VP-P
CMRR≥ 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential 300mV
Polarization Voltage ≥$500mV
Input Impedance ≥5 M
Calibration Voltage: 1mV 5%
Sp02
Measurement range: 0 ~ 100%
Resolution: 1%
Precision: 70% ~ 100% +2%
0% ~ 69%: no definition given
Pulse Rate
Measure/alarm range: 20 ~ 300bpm
Resolution: 1bpm
Accuracy $3bpm
NIBP
Method: Oscillometry
Measure mode: Manual, Auto, STAT
Measure interval in auto mode: 1~5/10/15/30/60/90/120/
180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40 ~ 240bpm|
Measure & alarm range:
Adult
SYS 40 ~ 280mmHg
DIA 10 ~ 220mmHg
MEAN 20 ~ 240mmHg
Pediatric
SYS 40 ~ 220mmHg
DIA 10 ~ 160mmHg
MEAN 20 ~ 170mmHg
Neonatal l
SYS 40 ~ 135mmHg
DIA 10 ~ 100mmHg
MEAN 20 ~ 110mmHg
Static pressure measurement
Range: 0 ~ 300mmHg
Accuracy 3mmHg
Resolution: 1mmHg Accuracy:
Max. Mean Error 5mmHg
Max. Standard Deviation: 8mmHg
• Overpressure protection:
Adult 300mmHg
Pediatric 240mmHg
Neonatal 150mmHg
ST Segment
ST Segment Range: -2.0mV ~ +2.0mV
Accuracy: Ranging -0.8 mV ~ +0.8mV, measuring error is #0.02mV or 10%,
The larger prevails.
No definition for other ranges.
RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3 ~ 3
Base Impedance range: 200 ~ 4000
Bandwidth: 0.3 ~ 2.5Hz
Gain: × 0.25, × 0.5, × 1, × 2, x 4
Resp rate:Measurement Range
Adult 0 ~ 120BrPM
Neonatal/Pediatric 0 ~ 150BrPM
Resolution: 1BrPM
Accuracy: 7 ~ 150BrPM ( 2BrPM)
0 ~ 6BrPM (unspecified)
Apnea Alarm: 10 ~ 40s
TEMP
Channel 2
Measure & alarm range: 0 ~ 50 °C
Resolution: 0.1 °C
Accuracy (no sensor) #0.1 °C (0~50 °C)
(excluding sensor error)
Standard accessories
ECG cable & electrodes
Sp02 sensor
TEMP probe
NIBP cuff & tube
Power cord
Lithium-ion battery
User manual
Optional
Etco2 (Optional)
Dual IBP (Optional)
Nellcor Spo2 (Optional)
Suntch Nibp (Optional)
Recorder (Optional)