E7LED2
E7LED Portable Patient Monitor

E7LED Portable Patient Monitor

For information about the pricing and offers related to this product, please connect with us via the button below or on WhatsApp.

Product Categories:

Product Description:

Short Description:

Model: E7LED

Display: 2.8 inch TFT sreen

Optional Configuration: Recorder,mobile trolley, balance arm.

Application: Yonker E7led patient monitor is suitable for patient transfer, ward round, community hospital, etc. And suitable for neonates, children, adults, the elderly and other kind of people.

Language: English, Spanish, Portugal, Poland, Russian, Turkish, French, Italian

Quality Standards and Classification

Anti-electroshock degree:
Classle quipment (internal power supply)
Protection degree of fluid intake: IPX1

Application Range

• Adult children

Display

• 2.8inch display +LED(Red/Green)

Environment

working environment conditions

Ambient temperature range: +5°C~40 °C;
Relative humidity range: 15% ~ 80%, no condensation
Atmospheric pressure range: 60 ~ 107kPa;

Shipping and storage conditions

Ambient temperature: -20°C~+55°C
Atmospheric pressure: 16kPa ~ 107kPa
Humidity range: 10% ~ 95%

Electrical Specifications

Input: AC 100~240V AC,
Power frequency: 50/60Hz,
Maximum input power: 70VA
Fuse specification: 2A 16V
Working method: continuous work
Internal lithium battery: 2000 mAh

Dimension and Weight

Product Size 246.5*146.4*50.7mm
Product weight 950g

Optional accessories

Monitor trolley (optional)
Wall Mount (optional)

Features

• 2 hours of working time

Temperature

Range 0~50°C
Resolution 0.1°C
Accuracy +0.1°C (without probe error)

NIBP

Adult systolic blood pressure: 40 ~270mmHg
Diastolic blood pressure: 10~210mmHg
Average pressure: 20~ ~230mmHg
Children systolic blood pressure: 40 ~ 200mmHg
Diastolic blood pressure: 10 ~ 150mmHg
Average pressure: 20 ~ 165mmHg
Neonatal systolic blood pressure: 40 ~ 135mmHg
Diastolic blood pressure: 10~95mmHg
Average pressure: 20 ~ 110mmHg
Static pressure range: 0 ~ 300mmHg
Static pressure accuracy: 3mmHg
Blood pressure accuracy:
maximum average error 5mmHg;
maximum standard deviation 8mmHg
Overvoltage Protection:
Adult mode: 300 mmHg#10mmHg
Child mode : 240mmHg10mmHg
Neonatal mode: 150mmg#10mmHg

Sp02

Measuring range 0 ~ 100%
Resolution 1%
The accuracy is within the range of 70% to 100%, and the measure ment error should be $4%;In the range of 0% to 69%, the measure ment error is undefined

Pulse Rate

Measuring range 25 ~ 250bpm
Resolution 1bpm
Accuracy ≤3bpm
Refresh time 1s

Standard accessories

Sp02 sensor
TEMP probe
Cuff & Tube
Power cable
Ground cable
Lithium-ion battery
User Manual

Enquire for

E7LED Portable Patient Monitor